* Type K/J, Pt 100 ohm, 4 display.* 4 channels ( T1, T2, T3, T4 ),

T1-T2 for Type K, Type J.

* 2 channels ( PT1, PT2 ) for

Pt 100 ohm.

* Type K : -199.9 to 1370 ℃.

* Type J : -199.9 to 1210 ℃.

* Pt 100 ohm : -199.9 to 850 ℃.

* ℃/℉, 0.1 degree/1 degree.

* Data hold, Record ( max., min. ).

* RS-232 interface.

* Data logger, 16,000 data point.

* DC 1.5V ( UM-4, AAA ) battery

x 6 or DC 9V adapter in.

T1, T2, T3, T4, T1-T2, Type J/K, Pt 100 ohm

4 CHANNELS THERMOMETER

FEATURES

* Type K/J, Pt 100 ohm, measurement with 4 display. Over Indication Show " - - - - - ".

* Show 4 channels display on the LCD at the same time. Data Hold Freeze the display reading.

* Type K : -199.9 to 1370 ℃. Memory Recall Maximum & Minimum value.

* Type J : -199.9 to 1210 ℃. Sampling Time Approx. 1 second.

* Pt 100 ohm : -199.9 to 850 ℃. of display

* ℃/℉, 0.1 degree/1 degree. Power off Auto shut off saves battery life or

* 4 channels ( T1, T2, T3, T4 ), T1-T2. manual off by push button.

* Microcomputer circuit provides intelligent function Data Output RS 232 PC serial interface.

and high accuracy. Operating 0 to 50 ℃.

* Manual and auto data logger, with flexible sampling Temperature

time selection, can save max. 16,000 reading data. Operating Less than 80% R.H.

* Records Maximum and Minimum readings with recall. Humidity

* Data hold function for freezing the desired value. Power Supply DC 1.5 V battery ( UM4, AAA ) x 6 PCs,

* Offset adjustment for the Type K and Type J measurement. or equivalent.

* Offset adjustment for the Pt 100 measurement. DC 9V adapter input.

* Measuring unit can select to ℃ or ℉. * AC/DC power adapter is optional.

* DC 1.5V ( UM-4, AAA ) battery x 6 PCs. Power Current Approx. DC 9 mA.

* Build in the input socket for DC 9V power adapter. Weight 310 g/0.68 lb.

* RS232 PC serial interface. Dimension 174 x 68 x 42 mm ( 6.9 x 2.7 x 1.7 inch ).

* Few panel buttons, easy operation. Accessories Instruction manual.................... 1 PC

* Built-in low battery indicator. Included

* Heavy duty & compact housing case. Optional * Type K thermocouple probe.

Accessories TP-01, TP-02A. TP-03, TP-04

GENERAL SPECIFICATIONS * Pt 100 ohm probe, TP-101.

Circuit Custom one-chip of microprocessor LSI * AC to DC 9V adapter.

circuit. * RS232 cable, UPCB-02.

Display LCD size : 52 mm x 38 mm * USB cable, USB-01

* Show 4 channels display on the * Data Acquisition software, SW-U801

display at the same time. * Data Logger software, SW-DL2005.

Display Unit ℃, ℉. * Soft carrying case, CA-05A.

Resolution 0.1 ℃, 0.1 ℉. * Hard carrying case, CA-06.

Channels T1, T2, T3, T4, T1-T2.

Sensor type Type K thermocouple probe. ELECTRICAL SPECIFICATIONS (23±5 ℃)

Type J thermocouple probe.

PT 100 ohm probe Type K, Type J thermocouple

* Cooperate with an 0.00385 alpha

coefficient, meet DIN IEC 751. Sensor Reso- Range Accuracy

Sampling Time Manual Push the data logger button Type lution

of Data Logger once will save data one time. Type K 1 ℃ 1000 to 1370.0 ℃ ± ( 0.5 % + 1 ℃ )

* Set the sampling to 0 second. 0.1 ℃ -199.9 to 999.9 ℃

Auto 1 second to 59 minutes and 1 ℉ 1000 to 2498 ℉ ± ( 0.5 % + 1.8 ℉ )

59 seconds. 0.1 ℉ -199.9 to 999.9 ℉

Data Logger Max. 16,000-point Data logger Type J 1 ℃ 1000 to 1210 ℃ ± ( 0.5 % + 1 ℃ )

number Type K, Type J, 4 channels ( T1, T2, T3, T4 ) 0.1 ℃ -199.9 to 999.9 ℃

* Memory use 4 data point space in the memory. 1 ℉ 1000 to 2210 ℉ ± ( 0.5 % + 1.8 ℉ )

Pt 100 ohm, 2 channels ( T1,T2 ) 0.1 ℉ -199.9 to 999.9 ℉

* Memory use 2 data point space in the memory. * Accuracy value is specified for the meter only.

T1-T2 * Type K probe TP-01 TP-02A, TP-03. TP-04 are the

* Memory use 4 data point space in the memory. optional accessories.

Temperature Automatic temp. compensation for the

Compensation cold junction both type K/J thermometer PT 100 ohm

Linear Linear Compensation for the full range.

Compensation Resolution Range Accuracy

Offset, Span Available for advanced calibration

Adjustment procedure. 0.1 ℃ -199.9 to 850 ℃ ± ( 0.4 % + 1 ℃ )

Probe Input Type K, Type J : 1 ℉ 1000 to 1562 ℉ ± ( 0.4 % + 1.8 ℉ )

Socket 2 pin thermocouple socket. 0.1 ℉ -199.9 to 999.9 ℉

Pt 100 ohm : 1 ℉ -200 to -327 ℉

Ear phone socket. * Pt 100 ohm probe TP-101 is the optional accessory.

 