Push keyboard setting, external trigger, RS232 DIGITAL STROBOSCOPE LUTRON DT-2269

Write a review
11,330,000 تومان
4349
Out of stock

ISO-9001, CE, IEC1010

FEATURES

* Push keyboard setting.

* External trigger input.

* RS232 computer interface output.

* Flash rate :

5 to 10,500 RPM/FPM.

0.083 to 175 Hz

* Display 14 mm LED, 6 digits.

* High resolution.

* Main function : Fine adjust, Coarse adjust, Multiply by 2, Divide by 2, Fast finder, Memory recall.

* Memorize 10 sets of measuring data.

* Crystal time base and microprocessor circuit, not necessary take any calibration procedures.

* Power supply : AC 110V/220V/230V, 50/60 Hz.

* Application for inspecting and measuring the speed of moving gears, fans, centrifuges, pumps, motors,

general industrial maintenance, production, quality control, laboratories, schools and colleges...

* DT-2269 is a microprocessor circuit design, high accuracy, digital readout STROBOSCOPE. Adjusting

the "Flash Rate" by push button keyboard, unique design in the world, easy operating & with intelligent

function. That is ideal for inspecting and measuring the speed of moving gears, fans, centrifuges,

pumps, motors and other equipment used in general industrial maintenance, production, quality control,

laboratories and as well as for schools and colleges for demonstrating strobe action.

* External trigger input.

* RS232 computer interface output.

 

SPECIFICATIONS

Display 14 mm ( 0.56" ) LED, 6 digits.

Set up unit Flash rate - RPM/FPM, Hz * FPM - flash per minute

Flash rate set up range

RPM 5 to 12,500 RPM.

Hz 0.083 to 175 Hz.

Resolution ( internal trigger )

RPM/FPM

0.1 RPM

5 to 999.9 RPM

1 RPM

1,000 to 9,999 RPM

10 RPM

10,000 to 12,500 RPM

Hz

 0.001 Hz

< 10 Hz

0.01 Hz

10 Hz - 99.99 Hz

0.1 Hz

100 - 208 Hz

Accuracy ± ( 0.15 % + 0.2 RPM ) rdg. < 1,000 RPM

± ( 0.5 % + 1 RPM ) rdg.

1,000 to 3,300 RPM

± 1 % FS.

3,301, to 12,500 RPM

rdg : reading, FS : full scale

Switch Select Function:

RPM, Hz

Fine adjust, Coarse adjust,

Multiply by 2, Divide by 2,

Fast finder, Memory recall.

Memory Can memorize 10 sets of measuring data.

Set up stability 1 digit within 10 minute.

Data output RS 232 computer interface.

External trigger Input signal : 5V to 30 V rms,

5 to 10,500 RPM.

0.083 to 175 Hz.

Power supply

 AC 110V 10%, 50/60 Hz.

or AC 220V 10%, 50/60 Hz.

or AC 230V 10%, 50/60 Hz.

Circuit

This stroboscope/tachometer

employs an custom one-chip

of microcomputer LSI circuit

& crystal control time base

which results in extraordinary

accuracy & high set up

stability over a wide, dynamic

range.

Power consumption: Less than 30 Watt.

Operating temp. 0 to 50 ℃ (32 to 122 ℉).

Operating humidity Less than 80% R.H.

Dimension 21 x 12 x 12 cm

( 8.3 x 4.8 x 4.8 inch ).

Weight 1Kg/2.2 LB.

Housing case Compact and impact plastic

injection case with plastic

mirror type reflector.

Calibration :

Crystal time base and microprocessor circuit, not necessary take any external calibration procedure if the

stroboscope working properly.

Accessories included:

Operation manual........1 PC.

Power cord..................1 PC.

Optional Accessory RS232 cable................UPCB-02

Operating duty Cycle:

For prolong life and safe operation, please adhere to the following duty cycle:

< 2000 RPM - 2 hours, 2000 to 3600 RPM - one hour,

3601 to 8000 RPM - 30 minutes, > 8000 RPM - 10 minutes.

* 10 min. cooling off period between cycles.

FLASH TUBE SPECIFICATIONS:

Flash tube Xenon lamp.

Flash Duration Approximately 60 to 1,000

microseconds.

Flash color Xenon white 6,500 K degree

Flash energy 4 Watts-seconds (joules).

Beam Angle 80 degrees.

Flash tube replacement:

It is required to change the

flash tube when the

instrument start to flash

irregularly at speeds of 3600

RPM/FPM or more.

OPERATIONS PROCEDURES :

Preparation (a) Plug unit into a properly grounded 110V AC, 220V AC or 230V AC outlet.

(b) Turn the power switch to " on " position.

(c) Determine the range switch to " Low " or " High " position.

Checking Speed When checking speed, care must be taken to insure that the strobe is flashing in

unison (one to one) with the object being monitored. A Stroboscope will also stop

motion at 2:1, 3:1, 4:1 et., this is normally referred to as harmonies. To be sure of

unison, turn the dial until two images appear - this will double the actual speed. Then

lower the flashing rate until a single and stationary image appears - this is the actual

true speed.

Checking Motion For motion analysis, simply locate the actual speed as mentioned above and then turn

the dial slowly up or down. This will give a slow motion effect allowing complete

inspection.

Remark When order the stroboscope, should inform the power supply type is AC 110V, or

220 V or 230V.

 

No reviews found