Power Clamp Meter LUTRON PC-6009

Write a review
4,390,000 تومان
3777
Out of stock

*Watt ( true power ), ACV, DCV, ACA, OHMS, Diode.

*Watt measurement via the inductive clamp jaw.

*Wide range for power measurement, max. value up to

10,000 watt.

* Design meet IEC 1010 safety requirement.

* Heavy duty ACA clamp meter, 600 A max. range.

* Compact & heavy duty ABS housing plastic case.

*Measure AC current by the inductive conductor.

* LSI circuit provides high reliability and durability.

* LCD display, clear readout

*Overload protection circuit is provided for all range.

GENERAL SPECIFICATIONS

Display 13 mm (0.5") LCD, 3 1/2 digits.

Max. indication 1999.

Measurement Watt (true power).

DCV, ACV, ACA, ohms, Diode.

Polarity Automatic Switching, " - " indicates

negative polarity.

Current Sensor Hall effect sensors.

Over-input Display shows " 1 " or " -1 ".

Watt Zero Built-in external adjustment knob.

Adjustment

Sampling Time Approx. 0.4 second.

Battery Heavy duty type or Alkaline battery.

DC 9V battery. 006P, MN1604 ( PP3 )

or equivalent.

Operating Temp. 0 to 50 ℃ ( 32 to 122 ℉ ).

Operating Less than 80% RH.

Humidity

Power Approx. DC 15 mA.

Consumption

Weight 480 g/0.88 LB (including battery).

Dimension HWD 230 x 74 x 38 mm.

(9.1 x 2.9 x 1.5 inch)

Conductor Size 73.5 mm ( 2.9 inch ) - out side.

Standard Operation manual.............. 1 PC.

Accessories Test lead (red & black)...... 1 pair.

Carrying Case Model : CA-05A

( Optional )

ELECTRICAL SPECIFICATIONS ( 23 ±5 ℃ )

Function Range Reso- Accuracy Overload

lution Protection

AC Watt 2,000 1 Watt ± ( 2.5% + 8d ) Volt input :

(true power) Watt AC 600V

* ref. remark 10,000 10 ± ( 3% + 5d ) Current input :

Watt AC 50A

DC voltage 200 V 0.1 V ± (0.8 % + 1 d ) DC 600 V.

AC voltage 600 V 1 V ± (1% + 2 d) AC 600 V.

OHMS 2 k ohm 1 ohm ± (1 % + 1 d) AC/DC 250 V

AC current 200 A 0.1 A ± (2% + 10 d) 1000 ACA

600 A 1 A ± (2% + 5 d) (within 1 min.)

Diode Short/non conductance, good/defect test

Continuity A continuity testing beeper is equipped, so when

Beeper checking circuits of shorts or opens, then it is

not necessary to look at the meter.

The Beeper sounds will be generated if

continuity is present.

 

No reviews found