Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W
Voltage & Current are the True RMS value.
True Power ( KW、MW、GW ) measurement.
Apparent Power ( KVA、MVA、GVA ) measurement.
Reactive Power ( KVAR MVAR、GVAR) measurement.
Watt-Hour ( WH、SH、QH、PFH ).
Power Factor( PF )、Phase Angle( Φ )
Voltage measurement range : 10 to 600 ACV
Current measurement range: 0.2A to 1200 ACA.
Programmable CT ratio (1 to 600) and PT ratio (1 to 1000).
ACV input impedance is 10 Mega ohms.
Safety Standard : IEC 1010, CAT III 600V
Built-in clock and Calendar, real time data record with SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/data/ hour/mimute/second ) to the Excel directly, then user can make the further data analysis by themselves.
Complete set with 4 PCs Test Leads, 4 PCs Alligator clips, 3 PCs Clamp Probe, AC to DC 9V adapter, 2 G SD memory card and Carrying bag.
Computer data output, can cooperate with USB Cable /USB-01 RS232 cable/UPCB-02 and Data Acquisition software, SW-U801-WIN.
Description : 3 Phase Power Analyzer; SD card real time data recorder
Features :
SD card real time data logger / recorder
3 PHASE POWER ANALYZER
3 phase/ 4 wire, 3 phase/ 3 wire,
1 phase/ 2 wire, 1 phase/ 3 wire
True rms measurement for ACA, ACV.
True power : W, KW, MW.
VA, KVA, MVA, VAR, KVAR, MVAR.
PF ( power factor) , phase angle.
KWH, KVAH, KVARH, PFH.
ACA : 0.1 A to 2, 000 A, ACV : 10.0 to 600.0 V.
Real time data logger with SD card.
RS232/ USB computer interface.
Display all measuring electrical wave shape.
* Analysis for 3 phase multi-power system, 1P/2W, Accessories * Instruction manual.......................1 PC
1P/3W, 3P/3W, 3P/4W Included * Test Leads (TL88-4AT)................. 1 Set (4 PCs)
* Voltage & Current are the True RMS value. * Alligator clips (TL88-4AC)..............1 Set (4 PCs)
* True Power ( KW、MW、GW ) measurement. * Clamp Probe ( CP-1200 ).............. 3 PCs
* Apparent Power ( KVA、MVA、GVA ) measurement. * AC to DC 9V adapter.....................1 PC
* Reactive Power ( KVAR MVAR、GVAR) measurement. * SD card ( 2 G )............................ 1 PC
* Watt-Hour ( WH、SH、QH、PFH ). * Carrying bag................................1 PC
* Power Factor( PF )、Phase Angle( Φ ). Optional * USB Cable , USB-01
* Voltage measurement range : 10 to 600 ACV Accessories * RS232 cable, UPCB-02
* Current measurement range: 0.2A to 1200 ACA. * Data Acquisition software,
* Programmable CT ratio (1 to 600) and PT ratio (1 to 1000). SW-U811-WIN
* ACV input impedance is 10 Mega ohms.
* Safety Standard : IEC 1010, CAT III 600V ELECTRICAL SPECIFICATIONS
* Built-in clock and Calendar, real time data record with
SD memory card , sampling time set from 2 to 7200 ACV
seconds. Just slot in the SD card into the computer, it
can down load the all the measured value with the Range Resolution Accuracy
time information ( year/month/data/ 10.0V to 600.0V 0.1V ± (0.5%+0.5V)
hour/mimute/second ) to the Excel directly, then user * Phase to neutral line
can make the further data analysis by themselves. 10.0V to 600.0V
* Complete set with 4 PCs Test Leads, 4 PCs Alligator * Phase to phase
clips, 3 PCs Clamp Probe, AC to DC 9V adapter,
2 G SD memory card and Carrying bag. ACA
* Computer data output, can cooperate with USB Cable
/USB-01 RS232 cable/UPCB-02 and Data Acquisition Range Resolution Accuracy
software, SW-U801-WIN. 20A 0.001A, < 10 A ± (0.5%+0.1A)
0.01A, ≧ 10 A
GENERAL SPECIFICATIONS 200A 0.01A, < 100 A ± (0.5%+0.5A)
0.1A, ≧ 100 A
Circuit Custom one-chip of microprocessor LSI 1200A 0.1A, < 1000 A ± (0.5%+5A)
circuit 1A, ≧ 1000 A
Display * LCD Size :
81.4 X 61 mm ( 3.2 X 2.4 inch ) Power factor
* Dot Matrix LCD (320 X 240 pixels )
with back light. Range Resolution Accuracy
Measurement * ACV 0.00 to 1.00 0.01 ± 0.04
* ACA
* AC WATT ( True Power ) Remark :
AC WATT( Apparent Power ) * PFH : Long term average power factor ( WH/SH )
AC WATT( Reactive Power ) * PFΣ :
* Power factor For 3Φ 4W, 3Φ 3W For 1Φ 3W
* Phase angle PFΣ = ( PF1 + PF2 + PF3 )/3 PFΣ = ( PF1 + PF2 )/2
* Frequency
Wire 1P/2W, 1P/3W, 3P/3W, 3P/4W.
connections
Voltage ranges 10 ACV to 600 ACV, auto range. Φ ( Phase angle )
Current ranges 0.2 ACA to 1200 ACA,
auto range/manual range. Range Resolution Accuracy
Safety IEC1010 CAT III 600 V. -180° to 180° 0.1° ± 1° * ACOS(PF)
standard
ACV input 10 Mega ohms. Frequency
impedance
Range select ACV Auto range. Range Resolution Accuracy
ACA Auto range & manual range. 45 to 65 Hz 0.1 Hz 0.1 Hz
Clamp 40 Hz to 1 KHz.
frequency Active (Real) Power
response
Spec. tested 45 to 65 Hz. Range Resolution Accuracy
frequency 0.000 to 9.999 KW 0.001 KW ± (1%+0.008 KW)
Over load ACV 720 ACV rms 10.00 to 99.99 KW 0.01 KW ± (1%+0.08 KW)
protection ACA 1300 ACA with clamp probe 100.0 to 999.9 KW 0.1 KW ± (1%+0.8 KW)
CP-1200 1.000 to 9.999 MW 0.001 MW ± (1%+0.008 MW)
Over Indicator Show " OL ".
Under Indicator Show " UR ". Apparent Power
Data Hold Freeze the display reading.
Data Record SD Card Record. Range Resolution Accuracy
Sampling Time Approx. 1 second. 0.000 to 9.999 KVA 0.001 KVA ± (1%+0.008 KVA)
Power ON/OFF Manual OFF by push button. 10.00 to 99.99 KVA 0.01 KVA ± (1%+0.08 KVA)
Real time * Real time data logger, saved the data 100.0 to 999.9 KVA 0.1 KVA ± (1%+0.8 KVA)
data logger into SD memory card and down load 1.000 to 9.999 MVA 0.001 MVA ± (1%+0.008 MVA)
the all the measured value with the
time information ( year/month/data/ Reactive Power
hour/mimute/second ) down load
to the Excel Range Resolution Accuracy
* Integration time for data logger : 0.000 to 9.999 KVAR 0.001 KVAR ± (1%+0.008 KVAR)
2 seconds to 7200 seconds, the during 10.00 to 99.99 KVAR 0.01 KVAR ± (1%+0.08 KVAR)
of setting step are 2 seconds. 100.0 to 999.9 KVAR 0.1 KVAR ± (1%+0.8 KVAR)
Data Output RS232 computer serial interface : 1.000 to 9.999 MVAR 0.001 MVAR ± (1%+0.008 MVAR)
USB/RS232 * Connect the optional USB cable
* Computer USB-01 will get the USB plug. Watt Hour ( Active Power Hour) : WH
interface * Connect the optional RS232 cable
UPCB-02 will get the RS232 Range Resolution Accuracy
plug. 0.000 to 9.999 KWH 0.001 KWH ± (2%+0.008 KWH)
Operating 0 to 50℃ ( 0 to 122℉ ). 10.00 to 99.99 KWH 0.01 KWH ± (2%+0.08 KWH)
Temperature 100.0 to 999.9 KWH 0.1 KWH ± (2%+0.8 KWH)
Operating Less than 80% R.H.. 1.000 to 9.999 MWH 0.001 MWH ± (2%+0.008 MWH)
Humidity
Power Supply * DC 1.5V, AA ( UM-3 ) Battery X 8 PCs VA Hour ( Apparent Power Hour ) : SH
(Alkaline or heavy duty battery).
* AC to DC 9V power adapter. Range Resolution Accuracy
Power * Meter : 300 DCmA. 0.000 to 9.999 KVAH 0.001 KVAH ± (2%+0.008 KVAH)
Consumption * Clamp : 20 DCmA. 10.00 to 99.99 KVAH 0.01 KVAH ± (2%+0.08 KVAH)
Clamp max. 86 mm ( 3.4 inch ) Dia. 100.0 to 999.9 KVAH 0.1 KVAH ± (2%+0.8 KVAH)
conductor 1.000 to 9.999 MVAH 0.001 MVAH ± (2%+0.008 MVAH)
Size
Weight * Meter: 1049g ( includes batteries ) VAR Hour ( Reactive Power Hour ) : QH
* Clamp : 522g
Dimension Meter : 225 X 125 X 64 mm Range Resolution Accuracy
( 8.86 X 4.92 X 2.52 inch ) 0.000 to 9.999 KVARH 0.001 KVARH ± (2%+0.008 KVARH)
Clamp : 210 X 64 X 33mm 10.00 to 99.99 KVARH 0.01 KVARH ± (2%+0.08 KVARH)
( 8.3 X 2.5 X 1.3 inch ) 100.0 to 999.9 KVARH 0.1 KVARH ± (2%+0.8 KVARH)
Clamp Jaw : 50 mm (2.0 inch)- outside 1.000 to 9.999 MVARH 0.001 MVARH ± (2%+0.008 MVARH)
PATENT CHINA : ZL 2008 2 0189918.5 ZL 2008 2 0189917.0 TAIWAN : M 358970 M 359043
Germany : Nr. 20 2008 016 337.4 JAPAN : 3151214 U.S.A. : Pending