Laser Target Light INFRARED THERMOMETER LUTRON TM-958

Write a review
1,690,000 تومان
3797
Out of stock

Infrared thermometer, non-contact temperature measurement, -30 to 300 ℃ ( -22 to 572 ℉ ), precision for none contact temperature measurement.

Microcomputer circuit with high performance.

Wide temperature measuring range.

Measurement via one operation button, easy to operate.

Build in ℃ & ℉ select switch.

Automatic data hold.

0.95 default emissivity value.

Emissivity value can adjust from 0.2 to 1.00.

Back light LCD display.

LCD display both temperature and the emissivity value.

Laser target guide for IR thermometer.

0.5 degree display resolution.

Auto power shut off saves battery life.

Built-in low battery indicator.

Compact housing case with stand.

Operates from 006P DC 9V battery.

GENERAL SPECIFICATIONS

Display LCD, 29 mm x 33 mm. Sampling Time Approx. 0.6 second.

* Main display to show temp. value. Hold and After release the operation switch,

* Lower display to show emissivity value. Auto Power display will hold the last measuring

* Back Light. Off function value within 5 seconds continuously.

Functions ℃, ℉, Over Indication ≧ 305 ℃, display will show 350 ℃ and flashed.

Auto data hold, ≦-30 ℃, display will show -30 ℃ and flashed.

Auto power off, Power Supply DC 9V battery, 006P, MN1604 ( PP3 )

Auto LCD back light, or equivalent, heavy duty or Alkaline.

Emissivity adjustment. Power Approx. DC 14 mA, with laser light out.

Measurement -30 to 300 ℃ ( -22 to 572 ℉ ), Consumption Approx. DC 25 mA, w/o laser light out.

Range Operating 0 to 50 ℃ (32 to 122 ℉).

Resolution 0.5 ℃/0.5 ℉. Temp. and Less than 80% RH.

Circuit Exclusive microcomputer circuit. Humidity

Emissivity Adjustment range : 0.20 to 1.00. Weight 140 g/0.3 LB ( without battery ).

Adjustment * 0.95 default emissivity value. Dimension 160 x 92 x 45 mm.

Target Guide * Less than 1 mW. ( 6.3 x 3.6 x 1.8 inch ).

* Class 2 laser diode. Red. Wave length Standard Operational manual..... 1 PC.

is 645 nm approximately. Accessory

ELECTRICAL SPECIFICATIONS

Measurement -30 to 300 ℃ ( -22 to 572 ℉ ), Temp. Sensor Thermocouple pie.

Range Emissivity * By push button.

Resolution 0.5 ℃/0.5 ℉. Setting range : 0.20 to 1.00.

Accuracy ± 3 % of reading or ± 3 ℃( 5 ℉), which * The default emissivity value is 0.95,

ever is greater. which will cover 90% of a typical

* Meter operating temp. within 23± 5 ℃ application.

and the emissivity value of Measurement 6 to 12 micro meter.

measurement target set to 0.95. Wave length

* Spec. tested under the 20 cm dia. Region

black body, the measuring distance Factor D/S : Approx. 7:1.

from the probe sensing Head is 30 cm. D - Distance, S - Spot.

 

No reviews found