Infrared THERMOMETER LUTRON TM-939

Write a review
890,000 تومان
3794
Out of stock

High Temp. + Type K/J/R/E/T

-20 ℃ to 650 ℃ Wide range IR temperature measurement.

Infrared thermometer, non-contact temperature measurement, -20 ℃ to 650 ℃ ( -4 ℉ to 1202 ℉ ), precision for none contact temperature measurement.

Emissivity adjustment for IR thermometer.

2 in 1, Infrared thermometer + Thermocouple ( Type K/J/T/E/R ) thermometer.

Thermocouple probe accepts 5 different types : type K, type J, type T, type E, type R. 

Microcomputer circuit with high performance.

Build in ℃ & ℉ select button on the front panel.

Data hold function for stored the desired value on display.

Memory function to record the maximum & minimum reading with recall. Build the REL button, useful for relative measurement.

Sensor select button on the front panel, easy to change different type probe.

RS 232 data output, easy cooperate with computer.

Optional data acquisition software for data record.

Auto power shut off saves battery life.

Built-in low battery indicator.

Heavy duty & compact housing case with stand.

006P DC 9V battery power supply.

GENERAL SPECIFICATIONS

Display 51 mm x 32 mm supper large LCD Memory Recall Memorize the Maximum, Minimum

display, 15 mm ( 0.6" ) digit size. reading with recall.

Offset For thermocouple thermometer offset

Measurement 1. Infrared thermometer Adjustment by pushing button on front panel.

( Non contact temperature measurement ) Over Indication Show " - - - - ".

2. Thermocouple probe, type K/J/T/E/R Data Output RS232 PC serial interface.

Functions ℃, ℉, Data hold, Memory ( Max., Min. ), Power Supply Alkaline or heavy duty type,

Relative measurement, DC 9V battery, 006P, MN1604 ( PP3 )

Emissivity adjustment (IR thermometer). or equivalent.

Resolution 1 degree or 0.1 degree. Power Approx. DC 10 mA ( laser guide off ).

Circuit Exclusive microcomputer circuit, the Consumption Approx. DC 19 mA ( with laser light on ).

software build in linearity correction * Above consumption value is calculated

instead the traditional hardware circuit. under the function of IR thermometer.

IR Emissivity Range : 0.20 to 1.00. Operating 0 to 50 ℃ (32 to 122 ℉).

Adjustment by pushing button on front panel. Temperature

IR Sensor Thermocouple pie. Operating Less than 80% RH.

IR Measure 6 to 12 micro meter. Humidity

Wave Length Weight 220 g/0.48 LB.

Region Dimension HWD 220 x 68 x 30 mm ( 8.7 x 2.7 x 1.2 inch ).

IR D/S ratio : Approx. 7 : 1. Standard Operational manual..............................1 PC.

Distance Factor * D - Distance, S - Spot. Accessory

Laser Guide Red laser light, less than 1 mW, Optional * Temperature probe :

Meet EN60825 accessories & TP-01, TP-02A, TP-03, TP-04

Probe Input Thermocouple probe : temp. probe * Carrying case, Model : CA-06, CA-03

Socket Standard 2 pin thermocouple socket. * RS232 cable, Model : UPCB-02

Sampling Time Approx. 1 second. * USB cable, Model : USB-01

Hold Function To freeze the display reading value. * Application software, windows version.

Model : SW-U801-WIN

MEASURING RANGE/ RESOLUTION

Type Reso- Range Accuracy Type Reso- Range Accuracy

lution

Infrared 1 ℃ - 20 ℃ to 650 ℃ - 20℃ to 400℃ : Thermocouple 0.1 ℃ -100.0 to -50.0 ℃ ± (0.2%+1℃)

thermometer 1 ℉ -4 ℉ to 1202 ℉ ± 3% of reading type T 0.1 ℃ -49.9 to 400.0 ℃ ± (0.2%+0.5℃)

or ± 3℃ ( 5℉ ) 0.1 ℉ -148.0 to -58.0 ℉ ± (0.2%+1.8℉)

> 400 ℃ : 0.1 ℉ -57.9 to 752.0 ℉ ± (0.2%+1℉)

± 3% of reading Thermocouple 0.1 ℃ -100.0 to -50.0 ℃ ± (0.2%+1.3℃)

Thermocouple 0.1 ℃ -100.0 to -50.0 ℃ ± (0.2%+1℃) type E 0.1 ℃ -49.9 to 900.0 ℃ ± (0.2%+0.8℃)

type K 0.1 ℃ -49.9 to 1300.0 ℃ ± (0.2%+0.5℃) 0.1 ℉ -148.0 to -58.0 ℉ ± (0.2%+2.8℉)

0.1 ℉ -148.0 to -58.0 ℉ ± (0.2%+1.8℉) 0.1 ℉ -57.9 to 1652.0 ℉ ± (0.2%+2℉)

0.1 ℉ -57.9 to 2372.0 ℉ ± (0.2%+1℉) Thermocouple 1 ℃ 0 to 600 ℃ ± (1 %+5℃)

Thermocouple 0.1 ℃ -100.0 to -50.0 ℃ ± (0.2%+1℃) type R 601 to 1700 ℃ ± (1.5%+5℃)

type J 0.1 ℃ -49.9 to 1150.0 ℃ ± (0.2%+0.5℃) 1 ℉ 32 to 1112 ℉ ± (1 %+10℉)

0.1 ℉ -148.0 to -58.0 ℉ ± (0.2%+1.8℉) 1113 to 3092 ℉ ± (1.5 %+10℉)

0.1 ℉ -57.9 to 2102.0 ℉ ± (0.2%+1℉)

OPTIONAL TEMPERATURE PROBE & OTHER ACCESSORIES

Carrying Case, CA-06 Model : CA-06, Hard carrying case

Carrying Case, CA-03 Model : CA-03, Vinyl soft carrying case.

Thermocouple Probe Measure Rage : -40 ℃ to 250 ℃, -40 ℉ to 482 ℉.

( Type K ) TP-01 Ultra fast response naked-bead thermocouple, general purpose application.

Thermocouple Probe Measure Range : -50 ℃ to 900 ℃, -50 ℉ to 1650 ℉.

( Type K ), TP-02A Dimension: 10 cm tube, 3.2 mm Dia.

Thermocouple Probe Measure Range : -50 ℃ to 1200 ℃, -50 ℉ to 2200 ℉.

( Type K ), TP-03 Dimension: 10 cm tube, 8 mm Dia.

Surface Probe Measure Range : -50 ℃ to 400 ℃, -50 ℉ to 752 ℉.

( Type K ), TP-04 Size : Temp. sensing head - 15 mm Dia. Probe length - 120 mm.

RS232 cable, UPCB-02 RS232 cable for connecting between the meter & the computer.

Application Software, Windows software apply as the performance of data logging system & data recorder...

 

No reviews found