3 in 1, Infrared thermometer + Pt 100 ohm+ Thermocouple (Type K/J/R/E/T), intelligent

The best professional thermometer in the world

Microcomputer circuit with high performance

Wide measuring range from -200 °C to 1700 °C

Patent pending

Built-in °C & °F select button on the front panel

0.1 degree resolution for Pt 100 ohm & type K/J/T/E

Data hold function for stored the desired value on display

Memory function to record the maximum & minimum reading with recall

Build the REL. button, useful for relative measurement

LCD display with back light

Sensor select button on the front panel easy to charge different type probe

Emissivity adjustment for IR thermometer 

Laser guide for IR thermometer 

Infrared thermometer, non-contact temperature measurement, -30°C to 350°C (14°F to 662°F) precision for none contact temperature measurement 

PT 100 probe input cooperate with an 0.00385 alpha coefficient, meet DIN IEC 751

Cooperate with 4 wires Ft-100 ohm probe, high precision

Thermocouple probe accept 5 different types :type K, type J, type R, type T, type E

RS 232 data output, easy cooperate with computer

Optional data acquisition software for data record

Auto power shut off saves battery life

Built-in low battery indicator

Heavy duty & compact housing case with stand

Standard accessory: 

ACCESSORIES

 

CA-03

Soft carrying case

CA-06

Hard carrying case

TP-100

100 Ohm probe (-50 ~ +400°C)

TP-100A

100 Ohm probe (-50 ~ +400°C)

TP-01

Thermocouple probe type K (-40 ~ +250°C)

TP-02A

Thermocouple probe type K (-50 ~ +900°C)

TP-03

Thermocouple probe type K (-50 ~ +1200°C)

TP-04

Thermocouple probe type K (-50 ~ +400°C)

UPCB-02

RS-232C cable

SW-U101-WIN

PC interface software

SPECIFICATIONS

 

Display:

51 mm x 32 mm super large LCD display, 15 mm (0.6") digit size

Probe type:

Infrared thermometer (Non contact temperature measurement)

Platinum PT-100 ohm

(0.00385 alpha coefficient, meet DIN IEC 751)

Thermocouple probe:

@Thermocouple type K.

@Thermocouple type J.

@Thermocouple type R.

@Thermocouple type T.

@Thermocouple type E.

Functions:

°C, °F, Data hold, Memory (max., min.)

Relative measurement.

LCD back light.

Emissivity adjustment (IR thermometer)

Resolution:

0.1 degree or 1 degree

Circuit:

Exclusive microcomputer circuit, the software build in linearity correction instead the traditional hardware circuit.

Laser guide:

Red laser light, less than 1 mW

Probe input socket:

PT 100 ohm probe: DIN 4pin socket

Thermocouple couple probe: Standard 2 pin type K socket

Sampling time:

Approx. 1 second

Hold function:

To freeze the display reading value

Memory recall:

Memorize the Maximum, Minimum reading with recall

Over indication:

Show " ----"

Data output:

RS-232 PC serial interface

Power supply:

Heavy duty or Alkaline DC 9V battery, 006P, MN1604 (PP3) or equivalent

Power consumption:

Approx. DC 9.5 mA (w/o laser light on)

Operating temperature:

0°C to 50°C( 32°F to 122°F)

Operating humidity:

Less than 80% RH

Size:

200 (H) x 68 (W) x 30 (D) mm (7.9 x 2.7 x 1.2 inch)

Weight:

220 gr. / 0. 48 LB

THERMOCOUPLE MEASUREMENTS 

 

 

Type 

Range 

Accuracy 

K- 0.1 °C

-100.0 ~ 1300.0°C

±(0.2% + 0.5°C)

J - 0.1 °C

-100.0 ~ 1150.0°C

±(0.2% + 0.5°C)

T - 0.1 °C

-100.0 ~ 400.0°C

±(0.2% + 0.5°C)

E - 0.1 °C

-100.0 ~ 900.0°C

±(0.2% + 0.5°C)

R - 0.1 °C

0 ~ 600°C

±(1% + 5°C)

 

601 ~ 1700.0°C

±(1.5% + 5°C)

 