.

DUAL THERMOMETER LUTRON TM-916

Write a review
2,550,000 تومان
3790
Out of stock

Microprocessor circuit assures

maximum possible accuracy, provides

special functions and features.

Super large LCD display.

Dual function meter's display.

* Heavy duty & compact housing case.

* Maximum and Minimum readings.

* Data hold.

* Auto shut off saves battery life.

* Operates from 006P DC 9V battery.

* T1, T2, T1-T2, 1 degree/0.1 degree

* Wide range from -200 to 1370 C degree.

* Meet any standard type K Temp. probe.

* Build in temperature linearity &

precision cold junction compensation

circuit, high accuracy.

* Fitted with standard type K

thermocouple input measuring socket.

* Microprocessor circuit assures maximum * Operates from OO6P DC 9V battery.

possible accuracy, provides special functions * Multi functions, dual channel temp. input,

and features. differential temp. measurement, ℃/℉, 0.1/1 degree,

* Super large LCD display, easy readout. data hold.

* Dual function meter's display. * Wide measuring range from -50 ℃ to 1230 ℃.

* Heavy duty & compact housing case. * Meet any standard type K(NiCr-NiAl) probe.

* Records Maximum and Minimum readings * Fitted with standard type K thermocouple input

with recall. measuring socket.

* Data hold. * Build in temperature linearity & precision cold

* Auto shut off saves battery life. junction compensation circuit, high accuracy.

* Low battery indicator.

GENERAL SPECIFICATIONS

Circuit Custom one-chip of micro- Memory Recall Records Maximum and

processor LSI circuit. minimum readings with

Display * 13 mm(0.5") Super large LCD recall.

display. Power Off Auto shut off saves battery life.

* Dual function meter's display. or manual off by push button.

Sensor Type Thermocouple K(NiCr-NiAl). Sampling Time Approx. 0.8 to 1.0 second.

Measurement Two channel temp. input (T1, Operating Temp. 0 ℃ to 50 ℃(32 ℉ to 122 ℉).

T2), differential temperature Operating Less than 80% R.H.

measurement(T1 -T2), Humidity

℃/℉, 0.11 data hold. Power Supply 006P DC 9V battery. (Heavy Duty

Range - 50 ℃ to 1230 ℃, Type).

- 50 ℉ to 1999 ℉. Power Current Approx. DC 6.2 mA.

Polarity Automatic switching, Weight 275 g/0.61 LB.

'-' indicates negative polarity. Dimension 180 x 72 x 32 mm.

Input 10 Mega ohm. (7.1 x 2.8 x1.3 inch).

Impedance Instruction manual...........1 PC.

Over input Indication of "- - - -". Optional Temperature probe.

indication Accessories Carrying case.

ELECTRICAL SPECIFICATIONS (23 5 ℃)

TEMP. RANGE RESOLUTION ACCURACY

-200 ℃ to 1370 ℃ 0.1 ℃ -199.9 ℃ to 199.9 ℃ ± ( 1 % + 1 ℃)

℃ 1 ℃ --200 ℃ to 1370 ℃

℉ -328 ℉ to 2498 ℉ 0.1 ℉ -199.9 ℉ to 199.9 ℉ ± ( 1 % + 2 ℉)

1 ℉ -328 ℉ to 2498 ℉

℃ T1 - T2 ± ( 1 % + 2 ℃)

℉ T1 - T2 ± ( 1 % + 3 ℉)

* The above accuracy specification applies only to the instrument itself and allowance must be made

for limits of error permitted in thermocouple.

OPTIONAL TEMPERATURE PROBE & OTHER ACCESSORIES

Soft carrying case, CA-03 Dimensions : 275 x 195 x 64 mm, Weight : 465 g.

Hard carrying case, CA-06 Dimensions : 210 x 100 x 70 mm, Weight : 81 g.

Thermocouple Probe Measure Range: -40 ℃ to 250 ℃, -40 ℉ to 482 ℉

(Type K) TP-01 Max. short-term operating Temperature: 300 ℃ (572 ℉).

It is an ultra fast response naked-bead thermocouple, suitable for

many general purpose application.

Thermocouple Probe Measure Range: -50 ℃ to 900 ℃ (-50 ℉ to 1650 ℉).

(Type K), TP-02A Dimension: 10cm tube, 3.2mm Dia.

Thermocouple Probe Measure Range: -50 ℃ to 1200 ℃ (-50 ℉ to 2200 ℉).

(Type K), TP-03 Dimension: 10cm tube, 8mm Dia.

Surface Probe Measure Range: -50 ℃ to 400 ℃ (-50 ℉ to 752 ℉).

(Type K), TP-04 Size: Temp. sensing head - 15 mm Dia, Probe length - 120 mm.

 

No reviews found