The ST451B combines automation, security, energy savings and ease of use.
It uses infrared energy detection signal as individuals and will shoot after a person enters the detection field.
It automatically identifies the day and night and is very easy to use.
Specification:
Detection Range: 360°
Power Source: 110-240V/AC
Power Frequency: 50/60Hz
Maximum lamp power and Rated Load: <60W
Detection Distance: 6m max (<24°C)
Time-Delay and Speed detection:
min. 10sec±3sec
max. 5min±1min
Ambient Light: 3-2000LUX (adjustable)
Installation Height: 2m-3.5m
Operating Temperature: -20 ~ +40 C
INSTALLATION
1-Place the sensor in the desired location in the diagram against.
2-Install the lamp
Fix the holder in the place where you will want to install according to right figure.
After installation of the sensor, connect with lamp, then you could test it.
TEST
After installation, Turned LUX knob clockwise to the maximum (SUN). Turned time knob anti-clockwise to the minimum(-).
Turn on the power, the sensor will be electrify and warm-up, 30 sec later, the item will be entered into working estate.
10~13 seconds after the light goes out for the first time and then sensing, the load should be worked.
Turns LUX knob anti-clockwise to the minimum.
If it is tested under the circumstance below 3LUX, load should not work after induction load stop working; but if you cover the detection window with opaque objects (towel etc), the load works.
Under the condition of no induction signals, the load should stop working within 10-13 sec.
Note : When testing in daylight , please turn LUX knob to "SUN" Position , otherwise the sensor lamp could not work.