Power Analyzer LUTRON DW-6090

3779
This power analyzer can measure the true power of the system. When using together with a current clamp it can measure up to 2,000kW.  Ideal for...
Full description
7,830,000 تومان
Out of stock
7,830,000 تومان

This power analyzer can measure the true power of the system. When using together with a current clamp it can measure up to 2,000kW.  Ideal for building facility management.

* RS-232 serial output interface

* Multi-functions: Watt, VA, W hr, Power factor, ACV, ACA, DCV, DCA, Hz, ohm

* True AC power measurement, not apparent power

* True RMS for ACV and ACA

* Display Watt, power factor, V and A simultaneously

* Auto range, Peak-hold and Data-hold

Multi-functions : WATT, VA, Whr,

PF ( Power factor ), ACV, ACA,

DCV, DCA, Hz, ohm.

* True AC power( Watt ) & apparent

power ( VA ) measurement.

* True rms display for ACV, ACA.

* Supper large LCD, display the Watt,

Power factor, Voltage & Current

value at the same time.

* Accept inductive clamp or CT input.

* Peak hold & data hold function.

* Hi, low alarm setting, RS-232/

 

FEATURES

* Multi-functions : WATT, VA, Whr, Power factor ACV, ACA, DCV, * Alarm Hi, low setting capability.

DCA, Hz, ohm. * RS-232 output interface.

* True AC power measurement, not apparent power. * Exclusive custom exclusive design LSI circuit, provides high

* True rms display for ACV, ACA. accuracy, reliability and durability.

* Supper large LCD, easy to read-out, display the Watt, Power factor, * Built-in over input indication.

Voltage & Current value at the same time. * Power supply by DC battery or AC to DC adapter.

* Current mode from direct input, inductive clamp probe or CT. * Built-in low battery indicator .

* Auto range. * Durable bench type housing plastic case with carrying handle.

* Built-in peak hold & data hold function.

GENERAL SPECIFICATIONS

Display * 93 mm x 52 mm large LCD ( Liquid Crystal Sampling Time W, A, V - 1.5 sec. DCV, DCA - 1 sec.

Display) display panel.. Operating Temp. 0to 50℃ ( 32 to 122 ℉).

* Multi-display unit, show Volt, Ampere, Watt, Operating Humidity Less than 80 % R.H..

Power factor at same time. Power Supply DC 9V, 1.5 V AA (UM-3) battery x 6 PCs.

Measurement WATT, VA, Whr,, Power factor ACV, ACA, Power Consumption Approx. DC 30 mA

DCV, DCA, Hz, ohm. Dimension 280 x 210 x 90 mm ( 11.0 x 8.3 x 3.5 inch ).

Zero Adjustment Watt : External adjustment. Weight Approx. 1,100 g ( 2.4 LB ).

DCV, ACV, DCA, ACA: Automatic adjustment. Standard Accessories Test lead(red & black)............1 pair.

Polarity Automatic switching, "-" indicates reverse polarity. Instruction Manual..................1 PC.

Current input mode Direct input, inductive clamp probe or CT. Optional RS232 cable, UPCB-02

Over input Indication Indication of " - - - - or " - - - - . Accessories USB cable, USB-01

Data Output RS232 serial interface. Data Acquisition software, SW-U801-WIN

ELECTRICAL SPECIFICATIONS (23±5 ℃)

Watt (AC, true power), current mode from direct input.

Range Resolution Accuracy Remark

1 Watt to 9,999 Watt 1 Watt ± ( 1.5 % + 1 d ) * Auto range.

10 K Watt to 99.99 K Watt 10 Watt * Frequency Characteristic: 45 Hz-65Hz.

* Accuracy is specified under input signal frequency of 50/60 Hz.

Watt (AC, true power), current from inductive probe or CT.

Range Resolution Accuracy Remark

1 Watt to 9,999 Watt 1 Watt ± ( 1.5 % + 1 d ) * Auto range.

10 KW to 99.99 KW 10 Watt * Frequency Characteristic: 45 Hz-65Hz.

100.0 KW to 999.9 KW 0.1 kW * Accuracy is specified under input signal frequency of 50/60 Hz.

1000 KW to 1999 KW 1 kW

VA ( AC ), current mode from direct input

Range Resolution Accuracy Remark

0.01 VA to 99.99 VA 0.01 VA ± ( 1.5 % + 1 d ) * Auto range.

100.0 VA to 999.9 VA 0.1 VA * Frequency Characteristic: 45 Hz-65Hz.

1000 VA to 9999 VA 1 VA * Accuracy is specified under input signal frequency of 50/60 Hz.

10.00 K VA to 39.99 kVA 10 VA

POWER FACTOR, current mode from direct input only

Range Resolution Accuracy

0.01 to 1.00 0.01 ± ( 1.5 % + 2 d )

AC VOLTAGE , DC VOLTAGE

Range Resolution Accuracy Input Impedance Overload circuit Protection

0.1 V to 299.9 V 0.1 V ± ( 1 % + 1 d ) 10 Mega ohm AC 700 V

300 V to 600 V 1 V DC 1000 V

Remark : Auto range.

AC CURRENT, DC CURRENT, current mode from direct input

Range Resolution Accuracy Voltage drop ( in case of full scale )

0.01 A to 20.00 A 10 mA ± ( 1 % + 1 d ) 2 V AC

* ACA, ACV frequency characteristic : 45 Hz to 65 Hz, specification be tested on sine wave of 50/60 Hz.

* Converter response : Average responding, calibrated to display RMS value of sine wave.

AC CURRENT DC CURRENT, current mode from inductive probe

Range Resolution Accuracy Remark

1 A to 1000 A 1 A ± ( 1 % + 1 d ) ACA : 1 AC mV per 1 AC ampere.

DCA : 1 DC mV per 1 DC ampere.

AC CURRENT, current mode from CT ( current transformer )

Range Resolution Accuracy Remark

CT 100/5A, 0.1 - 100.0 A 0.1 A Depend the CT its own

CT 1000/5A, 1 - 1000 A 1 A accuracy.

Watt Hour, current from direct input

Range Resolution Accuracy Remark

0.001 Whr to 9.999 Whr 0.001 Whr * Auto range.

10.00 Whr to 99.99 Whr 0.01 Whr ± ( 1 % + 1 d ) * Frequency Characteristic: 45 Hz-65Hz.

100.0 Whr to 999.9 Whr 0.1 Whr * Accuracy is specified under input signal frequency of 50/60 Hz.

1000 Whr to 9999 Whr 1 Whr

10 K Whr to 99.99 K Whr 10 Whr

100 K Whr to 999.9 K Whr 100 Whr

1000 K Whr to 9999 K Whr 1 K Whr

OHMS

Range Resolution Accuracy Overload Circuit Protection

1 ohm to 9,999 ohm 1 ohm ± ( 1 % + 1 d ) AC/DC 400V

10 K ohm to 19,99 K ohm 10 ohm

Hz

Range Resolution Accuracy Overload Circuit Protection

10.0 Hz to 99.9 Hz. 0.1 Hz ± ( 1 % + 1 d )

100 Hz to 999 Hz. 1 Hz

 

Watts (AC true power)

Direct input: 1W-100kW

Current probe: 1W-2,000kW

VA(AC)

Direct input: 0.01VA-40kVA

Power Factor:

0.01-1.00

ACV/DCV

0.1V-600V

ACA/DCA

Direct input: 0.01A-20A

Current probe: 1A-1000A

Watt Hour

Direct input: 0.001Whr-10,000kWhr

Ohms

1Ω -20MΩ

Frequency

0.1Hz-1kHz

Frequency Characteristics

45-65Hz

Size

11.0" x 8.3" x 3.5"

Weight

2.4 lb

Power

6 x AA battery or DC 9V(not included)

 

No reviews found