The MS-8050 is a high accuracy, high stability digital multimeter. It uses 24 bit A/D converter, completed dozens of measurements in the single chip computer control.
Direct digit display up to 53000 count.
With DC, AC RMS, mixed signal DC + AC RMS reaches as high as 1000V voltage, 10A current measurement function.
1 microvolt DC and 20KHz AC frequency resolution can satisfy most requirements for measurement.
It is a frequency meter, the pulse can be measured more than 2MHz frequency, linear frequency can reach 200KHz, including current frequency measurement.
Large 50M resistor, capacitor and 5000 u F maximum value, minimum value, relative value, average value, measured in decibels, diode, switching power on the technical staff very useful.
The instrument has 30 full storage function, double function display, color fluorescent digital display shows off the meter luxury.
MS8050 software was used to control and adjustment, adjustable components can ensure the long-term stability of the non high stability of the instrument. Instrument with photoelectric isolation of RS-232C interface and PC computer software, can be on the computer display, recording, measurement process mapping.
Mapping software with dynamic scale is unique, so that small changes in the measured parameters are clear picture recording.
MS8050 plus a computer becomes a multipurpose measuring recorder.
Misoperation function makes its safety performance is guaranteed.
It is the factory, scientific research institutions, school laboratory electrical measuring the best choice.
Features:
53000 counts VFD Display
ACV(TRMS)/ACV+DCV/dBm/DCV measurement up to 1000V
0.01Ω resistance and 1μV voltage resolution
Logic frequency/Linear frequency and duty cycle measurement
MAX/MIN/MAX-MIN Value, relative value, average value measurement
Data Hold and Data Logging
USB Interface
PC Analysis software
Diode and Continuity Test
20KHz frequency response for ACV measurement
220V/110V Power Supply
Characteristic.
Dual function of 53000 count display measurement
manual / automatic range selection
ACV and DCV measurements of 1000 Volts
DC measurement accuracy of 0.03%
resistance resolution and l u V 0.1 ohms voltage resolution
voltage / current linear frequency measurement, frequency measurement / dominant logic
capacitance from 0.01nF to 5000 u F
AC/AC +DC true effective value measurement
DBm measurement, calculation of resistance of 4 -1200 , a total of twenty choices
maximum signal / minimum / maximum - minimum value and relative value / average measurement
data retention
color fluorescent double functional screen
full screen storage function
RS232C infrared interface /PC display, record, make ring system
software automatic calibration / complete overload protection
the current file position error sound alarm
Technical indicators:
AC / DC voltage and AC voltage: 50mV/500mV/5V/50V/500V/IOOOV + 0.5
DC voltage: 50mV/500mV/5V/50V/500V/1000V 0.03%
AC / DC current of ten alternating current: 500 u A/5000 u A/50mA/500mA/5A + 0.75%, 10A + 1.5%
DC current: 500 u A/5000 u A/50mA/500mA/5A/1OA, 0.l5%
resistance: 5000/5K /50K /500K /5M + 0.1%, 50M + 0.5%
capacitor: 50nF/500nF/5 u F/50 u F l%, 500 u F/5000 u F + 2%
two transistor: 25V l%
duty ratio: 5KHz - 500KHz, range: 5% - 95%
Logic frequency: 5KHz - 2MHz + 0.006%, Vpp 2 - 5V square wave
linear frequency: 10Hz - 200KHZ soil is 0.006%, the lowest sensitivity: 5mV
display color VFD display
Characteristic:
Between the measuring end and the maximum voltage 1000V AC/DC. 1000V CAT II, pollution degree 2.
The 53000 count, automatic / manual range, the basic sampling rate of 2.5 times / sec.
In the MV, logic, resistance, capacitance, diode frequency measurement, maximum overload protection voltage to 250V (RMS), in the A/mA measurement, protection of current 0.64A, in the A measurement, the protection current 12.5A.
Ultra range indicating OL.
The insurance tube 0.63A/500V (A/mA end), 12.5A/500V (A), 0.5A/250V (power fuse)
Infrared coupling of RS - 232C interface.
The working temperature of 5 C ~ 30 C (relative humidity 0 ~ 80%),
31 ~ 41 C (relative humidity 0 ~ 50%).
Storage temperature from-20 C ~ 60 C (<=80% relative humidity).
Altitude working below 2000m,
Store below 10000m
No reviews found