4 1/2 digits, True RMS
* Design meet IEC 1010 safety requirement. AC Voltage (True RMS)
* 4 1/2 digits DMM, high precision. Range 200 mV/2/20/200/600 V
* Large LCD display with annunciators. Resolution 0.01 mV/0.1 m/1 m/10 m/0.1 V
* LCD display, easy read-out. Accuracy ± (0.8%+10d) -200mV,2V,20V,200V,600V
* True RMS measuring reading for ACV & ACA function. * spec. are tested under 50/60 Hz.
* With data hold function Input Impedance 10 M ohm.
* Compact & strong housing case. Over Load 500 DCV, 350 ACV, 15 seconds - 200mV range.
* Optional Holster case. Protection 600 DCV, 600 ACV - others.
* Full range optional adapters for EMF, Light, Humidity
DC/AC CLAMP current, Humidity, RPM, Pressure, Sound
High voltage measurement. DC Current
Range 200u/2m/20m/200m/10A
GENERAL SPECIFICATIONS Resolution 10n/100n/1u/10u/1mA
Display 15 mm(0.5") LCD, w/ annunciators, Accuracy ± (0.5%+5d) -200uA,2mA,20mA
4 1/2 digits Max. reading 19999 ± (0.8%+10d) -200mA
Measurement 28 ranges, DCV, ACV, DCA, ACA, ± (2%+5d) -10A
ohms, hFE, DIODE, Continuity Over Load 200u/2m/20m/200mA range :
Beeper. Protection 0.5A fuse protection
Polarity Automatic Switching, 10 A range :
'-' indicates negative polarity. Max. 10A ( no fuse ).
Zero Adjustment Automatic adjustment.
Over-input Indicator "1 " mark indication.
Sampling Time Approx. 0.4 second. AC Current(True RMS)
Operating Temp. 0 ℃ to 50 ℃ (32 ℉ to 122 ℉). Range 200u/2m/20m/200m/10A
Operating Humidity Less than 80% RH. Resolution 10n/100n/1u/10u/1mA
Power Supply 006 P DC 9V battery. Accuracy ± (0.8%+10d) -200uA,2mA,20mA,200mA
Power Consumption Approx. DC 1.6 mA. ± (2%+10d) -10A
Dimensions 185 x 87 x 39 mm * spec. are tested under 50/60 Hz.
(6.7 X 3.5 X 1.4 inch) Over Load 200u/2m/20m/200mA range :
Weight 320 g/0.71 LB Protection 0.5A fuse protection
Fuse The meter build in one fuse for 10 A range :
current range(200u/2m/20m/200mA) Max. 10A ( no fuse ).
protection, its spec. :
Rating - 500 mA
Size - 5 mm dia. x 20 mm OHMS
Accessories Red and Black Test Leads ....... 1 pair Range 200/2k/20k/200k/2M/20M ohm
Included Instruction Manual ................. 1 PC Resolution 0.01/0.1/1/10/100/1k ohm
Optional Light adapter LX-02 Accuracy ± (0.5%+5d) -200 ohm
Accessories Anemometer adapter, AM-402 ± (0.3%+5d) -2k,20k,200k,2 M ohm
Humidity adapter, HA-702 ± (0.8%+3d) -20 M ohm.
tachometer adapter TA-601 Over Load 400 DCV, 350 ACV.
1000 A DC/AC current adapter, CA-501 Protection
2000 A DC/AC current adapter, CA-203
Mini ACA current adapter, CA-201
EMF adapter, EMF-824 Diode Check
Sound adapter, SL-406 Range Approx. forward voltage(VF),
50 A current shunt, ST-50 good/defect test.
High voltage probe, HV-40 Resolution 0.1 mV.
Carrying case CA-03, CA-05A
Alligator test lead, TL-02S
Alligator test lead, TL-02S Transistor hFE
Heavy duty alligators, AL-04 0-1000 hFE, NPN/PNP.
ELECTRICAL SPECIFICATIONS (23±5 ℃)
DC Voltage Data hold
Range 200 mV / 2 V/ 20 V/ 200 V / 600 V To freeze the display values.
Resolution 0.01 mV / 0.1 mV /1 mV /10 mV / 0.1 V
Accuracy ± (0.1%+2d)-200mV.
± (0.2%+2d)-2V,20V,200V,600V. Continuity
Input Impedance 10 M ohm. Sound beeper for continuity check.
Over Load 500 DCV, 350 ACV, 15 seconds - 200mV range. Beeper will sound if the measuring resistance < 250 ohm
Protection 600 DCV, 600 ACV - others. approximately.