measurement.* ACA 40 mA x 0.01 mA
* ACA 400 mA x 0.1 mA
* ACA 40 A, 120 A.
* True RMS
* AC voltage, DC voltage.
* Ohms, Diode, Continuity
beeper, hold.
* LCD display.
* DC 1.5V battery ( UM-3, AA )
x 2 PCs.
ACA LEAKAGE TESTER
Model : DL-9954
FEATURES
* High precision AC mA measurement, it is useful for AC Optional Carrying case, CA-52A
mA leakage current measurement. Accessories Light Adapter
* Measure AC mA on the inductive conductor. Anemometer Adapter
* Design meet IEC 1010 CATIII 600V safety requirement. Pressure Adapter
* 4000 counts, auto range and multi-functions. Humidity Adapter
* Measurement for ACA, ACV, DCV, Ohms, Diode, Tachometer Adapter
Continuity beeper. Sound level Adapter
* True RMS measuring reading for ACV and ACA function. High Voltage Probe.
* Two AC leakage current range : 40 mA, 400 mA .
* Two AC current range : 40 A, 120 A. ELECTRICAL SPECIFICATIONS (23±5 ℃ )
* Data hold. Function Range Reso- Accuracy Overload
* Relative measurement. lution Protection
* Crystal time base, high quality. DCV 400 mV 0.1 mV ± ( 0.5 % + 2d )
* LCD display allows clear readout-out even at high DC only
ambient light level. ACV 4 V 0.001V DCV :
* LSI circuit provides high reliability and durability. ( true rms ) 40 V 0.01V ± ( 1 % + 2d )
* Overload protection circuit is provided for all range. 400 V 0.1 V ACV : AC/DC 600V
* Compact & heavy duty ABS housing fireproof plastic 600 V 1 V ± ( 1.2 % + 5d )
case. ACA 40 mA 0.01mA
Leakage ± ( 1.5 % + 3d )
GENERAL SPECIFICATIONS ( true rms ) 400 mA 0.1mA
Display 10.8 mm ( 0.39" ) LCD, 3 1/2 digits, 0.1 to 400 mA
Max. indication 4000. 40 A 0.01 A
Measurement ACA, ACV, DCV, Ohms, Diode, ACA ± ( 1.5 % + 3d ) AC 120 A
Range Continuity beeper, Relative. ( true rms ) 120 A 0.1 A
Polarity Automatic Switching, " - " indicates 0.01 to 120 A
negative polarity. Remark * True RMS measuring reading for ACV and ACA function.
* Input impedance for ACV & DCV range is 10 Meg ohm.
Over-input Indication of " OL ". * ACA, ACV frequency response is from 40 to 1 KHz.
Sampling Time Approx. 0.35 second. * ACA, ACV specification be tested on sine wave 50/60 Hz.
Battery 2 x 1.5 V AA ( UN-3 ) batteries.
Operating 0 to 50 ℃ ( 32 to 122 ℉ ). Function Range Reso- Accuracy Overload
Temperature lution Protection
Operating Less than 80% RH. Ohms 400 ohm 0.1 ohm
Humidity 4 K ohm 1 ohm
Weight 251 g/0.55 LB ( including battery ). 40 K ohm 10 ohm ± ( 1 % + 5d )
Dimension HWD : 191 x 64.5 x 36.1 mm 400 K ohm100 ohm
( 7.5 x 2.5 x 1.4 inch ) 4 M ohm 1 K ohm ± ( 2 % + 2d ) AC / DC 400 V
Max. Jaw 22.3 mm ( 0.88 inch ) Dia. 40 M ohm 10Kohm ± ( 3.5 % + 5d )
Open Size Diode Short/non conductance, good/defect test.
Accessories Operation manual.................... 1 PC. Continuity If measuring resistance is less than 10 ohm,
Included Test lead (red & black)............ 1 PC. the beeper will sound .