.
.

Hioki 3169-20 Power Analyzer and Datalogger Kit

Write a review
Contact us for a price
32023
Out of stock

Hioki 3169-20 Power Analyzer and Datalogger Kit

KEY FEATURES:

• Memory card slot for extra long recording

• Phasor Diagram and waveform display

• User friendly menu driven operation

• True RMS Measurements

• Cycle by cycle recording

• Four current input channels

• Flexible Current Probe Available

• Real-time, onscreen analysis

• Compact, lightweight design

 

Simultaneously measure demand and harmonic waveforms that share the same voltage line over 4-circuits

Data can be saved onto a PC card

High-speed and continuous processing to measure individual waveforms

Measurement line & number of circuits Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit)

Note: 50 or 60 Hz, and that share the same voltage line

Measurement items Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value

Voltage ranges 150.00 V to 600.00 V AC, 3 ranges

Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use)

Power ranges 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line)

Basic accuracy AC Voltage: ±0.2 % rdg. ±0.1 % f.s.

AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy

Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1)

CLAMP ON SENSOR 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each model)

Measurement method Digital sampling, PLL synchronization or 50/60 Hz fixed clock

Basic accuracy Active power: ±0.2% rdg. ±0.1% f.s. + clamp-on sensor accuracy (at 45 to 66 Hz)

Display refresh rate 2 times /sec (except when using a PC card while accessing the internal memory, or when performing RS-232C communications)

Data save interval Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects

Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only)

Frequency characteristics Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45 to 66 Hz fundamental waveform)

Other functions Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, ±5 V DC f.s.)

Power supply 100 to 240 V AC, 50/60 Hz, 30 VA max.

 

Dimensions, mass 210 mm (8.27 in) W × 160 mm (6.30 in) H × 60 mm (2.36 in) D, 1.2 kg (42.3 oz)

No reviews found